Product Notifications
Engineering Change Notification
Public | Finalized Published: 8 February 2019 - Reference: 02_2019_ECN
TAGS: [Firmware] |
BIOS update for HT B30
For those customers that may have experienced this issue, the typical failure rate is (MTBF) 100h-1000h for systems equipped with m.2 SSD and >1500h for system equipped with 2.5" SSD.
The root cause is related to the signal quality of SVID signals, affecting the transition of SVID communication for CPU frequency/voltage.
Solution for units in field is BIOS update, which inhibit use of SVID communication.
HT B30xx xxC-xxx-xxxxxx
Notice: Customized models are ALSO affected by this Engineering Change Notification.

Effective from:Units delivered after 4 Feb 2019 updated during production. |
Changes:
- Disable of Turbo mode and SpeedStep. |
Additional information:
BIOS version for Intel® i5/i7 CPU: |
Contact:For further enquiries regarding this Engineering Change Notification, please contact Support at Hatteland Technology AS. |
Attachments:
CORRECTIVE ACTION REPORT / STATEMENT
(332.4kb) car_qar_143175.pdf BIOS update instructions (126.3kb) bios_update_instructions.pdf |
Matching products online:
HT B30Kx STC-xxx-ExxxxxHT B30Gx STC-xxx-Mxxxxx
HT B30Gx STC-xxx-Mxxxxx (HW00)
Implemented by:
________________________________
Frode Grindheim
VP Products
Hatteland Technology AS
Document sent to customers.
Reference: MAI/225022